Phosphate Test 2.0
Published in:
- CHIMIA International Journal for Chemistry. - 2013, vol. 67, no. 11, p. 819–821
English
The accurate measurement of the phosphate content of a liposomal suspension is important when working with differential scanning calorimetry. Standard phosphate tests date back several decades and require extended hands-on time. Here, we present a rapid version of a phosphate test taking advantage of microwave-assisted chemical digestion and multiwell plate reading technology allowing for the fast and accurate testing of many samples in parallel.
-
Faculty
- Faculté des sciences et de médecine
-
Department
- Département de Chimie
-
Language
-
-
Classification
-
Chemistry
-
License
-
License undefined
-
Identifiers
-
-
Persistent URL
-
https://folia.unifr.ch/unifr/documents/303425
Statistics
Document views: 36