Clinical Fitting and Adjustment Time for Implant-Supported Crowns Comparing Digital and Conventional Workflows.
Journal article

Clinical Fitting and Adjustment Time for Implant-Supported Crowns Comparing Digital and Conventional Workflows.

  • Joda T Department of Reconstructive Dentistry, University of Bern, Bern, Switzerland. tim.joda@zmk.unibe.ch.
  • Katsoulis J Department of Reconstructive Dentistry, University of Bern, Bern, Switzerland.
  • Brägger U Department of Reconstructive Dentistry, University of Bern, Bern, Switzerland.
  • 2015-09-24
Published in:
  • Clinical implant dentistry and related research. - 2016
English PURPOSE
The aim of this prospective cohort study was to investigate clinical and laboratory performance of implant-supported reconstructions comparing the digital to the conventional workflow.


MATERIALS AND METHODS
Twenty study participants were treated in a cross-over design for single-tooth replacement in posterior sites, each with a customized titanium abutment plus computer-assisted design and computer-assisted manufacturing (CAD/CAM)-zirconia-suprastructure (test: digital workflow; n = 20) and a standardized titanium abutment plus PFM-crown (control: conventional pathway; n = 20). Evaluation of the 40 reconstructions included: 1) feasibility of laboratory cross-mounting of each abutment-crown-connection, and 2) assessment of adaptation time for clinical adjustments of interproximal and occlusal surfaces. Statistical analyses were performed using the exact Wilcoxon rank sum tests.


RESULTS
Laboratory cross-mounting was feasible for three reconstruction pairings revealing a 15% vice versa transfer success rate. All implant crowns could be provided successfully within two clinical appointments, independently of the workflow used. The mean clinical adjustment time was significantly lower (p < .001) for test reconstructions from the digital workflow with 2.2 min (standard deviation [SD] ± 2.1) compared with the ones from the conventional pathway with 6.0 min (SD ± 3.9).


CONCLUSIONS
The digital workflow was almost threefold more efficient than the established conventional pathway for fixed implant-supported crowns. Clinical fitting could be predictably achieved with no or minor adjustments within the digital process of intraoral scanning plus CAD/CAM technology.
Language
  • English
Open access status
closed
Identifiers
Persistent URL
https://folia.unifr.ch/global/documents/263571
Statistics

Document views: 30 File downloads: