  <dc:description xmlns:ns0="xml" ns0:lang="en">Objective&#13;
We audited deployment readiness of an end-of-surgery postoperative infection model across clinically relevant subgroups and assessed mitigation of subgroup miscalibration.&#13;
&#13;
Materials and Methods&#13;
We analyzed out-of-fold predictions from 10 719 procedures (2014-2022) with 504 present-on-admission (POA)–coded postoperative infection events across recorded sex, age, and a clinical physiological-reserve proxy. We assessed discrimination, calibration, threshold-specific errors, and decision-curve net benefit, treating t = 0.10 as a reference anchor. We compared no recalibration with common and group-specific cross-fitted isotonic recalibration, evaluated a refit without the Synthetic Minority Oversampling Technique (SMOTE), and performed a temporal-holdout analysis.&#13;
&#13;
Results&#13;
Overall area under the receiver operating characteristic curve (AUROC) was 0.876, with similar sex-marginal discrimination in women and men (0.878 vs 0.875). Calibration-in-the-large was −1.02 overall, −0.86 in frail, and −1.34 in prefrail patients; the 6-event nonfrail stratum was not estimable. At t = 0.10, net benefit was positive in frail and negative in prefrail patients in the source cohort, but negative prefrail utility did not persist in the ascertainable-period (2018-2022) and temporal analyses. Common recalibration moved overall calibration-in-the-large from −1.020 to −0.007. Removing SMOTE shifted overall calibration but did not reduce the reserve gradient. Temporal-holdout AUROC was 0.851 with persistent overprediction. Present-on-admission coding was effectively absent before 2018; prevalence-dependent results were therefore additionally reported for the ascertainable 2018-2022 period, and ascertainment differed by physiological reserve.&#13;
&#13;
Discussion&#13;
Discrimination-only or sex-marginal evaluation would have missed deployment-relevant subgroup heterogeneity, while endpoint ascertainment affected prevalence-dependent interpretation.&#13;
&#13;
Conclusion&#13;
Joint subgroup evaluation can identify deployment-relevant limitations missed by aggregate metrics. Prospective validation with comparable outcome ascertainment remains necessary before clinical deployment.</dc:description>
  <dc:format>application/pdf</dc:format>
  <dc:identifier>https://folia.unifr.ch/unifr/documents/337381</dc:identifier>
  <dc:identifier>https://folia.unifr.ch/documents/337381/files/2026isitfairjamia.pdf</dc:identifier>
  <dc:identifier>https://folia.unifr.ch/documents/337381/files/ocag184_supplementary_data.pdf</dc:identifier>
  <dc:language>eng</dc:language>
  <dc:relation>https://doi.org/10.1093/jamia/ocag184</dc:relation>
  <dc:relation>info:eu-repo/semantics/altIdentifier/doi/10.1093/jamia/ocag184</dc:relation>
  <dc:relation>info:eu-repo/semantics/altIdentifier/issn/1527-974X</dc:relation>
  <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
  <dc:rights>CC BY</dc:rights>
  <dc:source>Journal of the American Medical Informatics Association. - Oxford Academic. - 2026, p. ocag184</dc:source>
  <dc:subject xmlns:ns1="xml" ns1:lang="en">machine learning</dc:subject>
  <dc:subject xmlns:ns2="xml" ns2:lang="en">postoperative infection</dc:subject>
  <dc:subject xmlns:ns3="xml" ns3:lang="en">algorithmic bias</dc:subject>
  <dc:subject xmlns:ns4="xml" ns4:lang="en">algorithmic fairness</dc:subject>
  <dc:subject xmlns:ns5="xml" ns5:lang="en">health equity</dc:subject>
  <dc:subject xmlns:ns6="xml" ns6:lang="en">clinical prediction models</dc:subject>
  <dc:subject>info:eu-repo/classification/udc/616</dc:subject>
  <dc:title xmlns:ns7="xml" ns7:lang="en">Subgroup deployment-readiness audit of calibration and clinical utility in perioperative infection prediction</dc:title>
  <dc:type>http://purl.org/coar/resource_type/c_6501</dc:type>