  <dc:description xmlns:ns0="xml" ns0:lang="en">Transplantation of kidneys from deceased donors is still associated with a high rate of  postoperative renal dysfunction. During implantation into the recipient, the kidney  rewarms. This second warm ischaemia time, which is not monitored, is harmful  especially if prolonged. We recently developed an intra-abdominal cooling device that  efficiently prevents kidney rewarming during robotic transplantation, and prevents  ischaemia-reperfusion injuries. We tested the benefits of this cooling device during  open kidney transplantation in pigs.METHODS: Kidneys were procured from large  pigs by open bilateral nephrectomy. Following procurement, kidneys were flushed with  4°C Institut Georges Lopez-1 preservation solution, and placed on ice. Animals then  underwent double sequential autologous open renal transplantation with (n = 7) and  without (n = 6) intra-abdominal cooling.RESULTS: Mean anastomosis time was similar  between groups (43.9 ± 13 minutes). At reperfusion, the renal cortex temperature was  lower in the group with cooling (4.3 ± 1.1°C vs 26.5 ± 5.5°C, p &lt;0.001). The cooled  kidneys tended to be protected from injury, including some histopathological  ischaemia-reperfusion lesions. With the device, kidneys had a better immediate  postoperative urine output (p = 0.05).CONCLUSION: Our results indicate that the  intra-abdominal cooling device significantly reduced second warm ischaemic time  during transplantation, is technically safe and does not prolong anastomotic time.</dc:description>
  <dc:format>application/pdf</dc:format>
  <dc:identifier>https://folia.unifr.ch/global/documents/308355</dc:identifier>
  <dc:identifier>https://folia.unifr.ch/documents/308355/files/bue_iia.pdf</dc:identifier>
  <dc:language>eng</dc:language>
  <dc:relation>info:eu-repo/semantics/altIdentifier/doi/10.4414/smw.2019.20143</dc:relation>
  <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
  <dc:rights>License undefined</dc:rights>
  <dc:source>Swiss Medical Weekly. - 2019, vol. 149, no. 5152, p. w20143</dc:source>
  <dc:subject>info:eu-repo/classification/udc/61</dc:subject>
  <dc:title xmlns:ns1="xml" ns1:lang="en">Impact of an intra-abdominal cooling device during open kidney transplantation in pigs</dc:title>