<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:creator>Bohmer, Nils</dc:creator>
  <dc:creator>Demarmels, Nino</dc:creator>
  <dc:creator>Tsolaki, Elena</dc:creator>
  <dc:creator>Gerken, Lukas</dc:creator>
  <dc:creator>Keevend, Kerda</dc:creator>
  <dc:creator>Bertazzo, Sergio</dc:creator>
  <dc:creator>Lattuada, Marco</dc:creator>
  <dc:creator>Herrmann, Inge K.</dc:creator>
  <dc:date>2017-09-06</dc:date>
  <dc:description xmlns:ns0="xml" ns0:lang="en">The magnetic separation of pathogenic compounds from body fluids is an appealing  therapeutic concept. Recently, removal of a diverse array of pathogens has been  demonstrated using extracorporeal dialysis-type devices. The contact time between  the fluid and the magnetic beads in such devices is limited to a few minutes. This  poses challenges, particularly if large compounds such as bacteria or cells need to be  removed. Here, we report on the feasibility to remove cells from body fluids in a  continuous dialysis type of setting. We assessed tumor cell removal efficiencies from  physiological fluids with or without white blood cells using a range of different  magnetic bead sizes (50–4000 nm), concentrations, and contact times. We show that  tumor cells can be quantitatively removed from body fluids within acceptable times (1– 2 min) and bead concentrations (0.2 mg per mL). We further present a mathematical  model to describe the minimal bead number concentration needed to remove a  certain number of cells, in the presence of competing nonspecific uptake. The present  study paves the way for investigational studies to assess the therapeutic potential of  cell removal by magnetic blood purification in a dialysis-like setting.</dc:description>
  <dc:format>application/pdf</dc:format>
  <dc:identifier>https://folia.unifr.ch/global/documents/305931</dc:identifier>
  <dc:identifier>https://folia.unifr.ch/documents/305931/files/lat_rcb.pdf</dc:identifier>
  <dc:identifier>https://folia.unifr.ch/documents/305931/files/lat_rcb_sm.pdf</dc:identifier>
  <dc:language>eng</dc:language>
  <dc:relation>info:eu-repo/semantics/altIdentifier/doi/10.1021/acsami.7b10140</dc:relation>
  <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
  <dc:rights>License undefined</dc:rights>
  <dc:source>ACS Applied Materials &amp; Interfaces. - 2017, vol. 9, no. 35, p. 29571–29579</dc:source>
  <dc:subject>info:eu-repo/classification/udc/54</dc:subject>
  <dc:title xmlns:ns1="xml" ns1:lang="en">Removal of cells from body fluids by magnetic separation in batch and continuous mode: influence of bead size, concentration, and contact time</dc:title>
  <dc:type>http://purl.org/coar/resource_type/c_6501</dc:type>
</oai_dc:dc>
