<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:creator>Fares, Elie-Jacques</dc:creator>
  <dc:creator>Isacco, Laurie</dc:creator>
  <dc:creator>Monnard, Cathriona R.</dc:creator>
  <dc:creator>Miles-Chan, Jennifer L.</dc:creator>
  <dc:creator>Montani, Jean-Pierre</dc:creator>
  <dc:creator>Schutz, Yves</dc:creator>
  <dc:creator>Dulloo, Abdul G.</dc:creator>
  <dc:date>2017-05-01</dc:date>
  <dc:description xmlns:ns0="xml" ns0:lang="en">Standardized approaches to assess human energy expenditure (EE) are well defined  at rest and at moderate to high‐intensity exercise, but not at light intensity physical  activities energetically comparable with those of daily life (i.e., 1.5–4 times the resting  EE, i.e., 1.5–4 METs). Our aim was to validate a graded exercise test for assessing  the energy cost of low‐intensity dynamic work in physically inactive humans, that is,  those who habitually do not meet the guidelines for moderate‐to‐vigorous aerobic  physical activity levels. In healthy and inactive young men and women (n = 55; aged  18–32 years), EE was assessed in the overnight‐fasted state by indirect calorimetry at  rest and during graded cycling between 5 and 50W for 5 min at each power output on a  bicycle ergometer. Repeatability was investigated on three separate days, and the  effect of cadence was investigated in the range of 40–90 rpm. Within the low power  range of cycling, all subjects perceived the exercise test as “light” on the Borg scale,  the preferred cadence being 60 rpm. A strong linearity of the EE‐power relationship  was observed between 10 and 50 W for each individual (r &gt; 0.98), and the calculation  of delta efficiency (DE) from the regression slope indicated that DE was similar in men  and women (~29%). DE showed modest inter‐individual variability with a coefficient of  variation (CV) of 11%, and a low intra‐individual variability with a CV of ~ 5%. No  habituation or learning effect was observed in DE across days. In conclusion, the  assessment of the efficiency of low power cycling by linear regression – and  conducted within the range of EE observed for low‐intensity movements of everyday  life (1.5–4 METs) – extends the capacity for metabolic phenotyping in the inactive  population.</dc:description>
  <dc:format>application/pdf</dc:format>
  <dc:identifier>https://folia.unifr.ch/unifr/documents/305618</dc:identifier>
  <dc:identifier>https://folia.unifr.ch/documents/305618/files/dull_rlp.pdf</dc:identifier>
  <dc:language>eng</dc:language>
  <dc:relation>info:eu-repo/semantics/altIdentifier/doi/10.14814/phy2.13233</dc:relation>
  <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
  <dc:rights>License undefined</dc:rights>
  <dc:source>Physiological Reports. - 2017, vol. 5, no. 9, p. e13233</dc:source>
  <dc:subject>info:eu-repo/classification/udc/613.2</dc:subject>
  <dc:title xmlns:ns1="xml" ns1:lang="en">Reliability of low‐power cycling efficiency in energy expenditure phenotyping of inactive men and women</dc:title>
  <dc:type>http://purl.org/coar/resource_type/c_6501</dc:type>
</oai_dc:dc>