<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:creator>Gori, Tommaso</dc:creator>
  <dc:creator>Jansen, Thomas</dc:creator>
  <dc:creator>Weissner, Melissa</dc:creator>
  <dc:creator>Foin, Nicolas</dc:creator>
  <dc:creator>Wenzel, Philip</dc:creator>
  <dc:creator>Schulz, Eberhard</dc:creator>
  <dc:creator>Cook, Stéphane</dc:creator>
  <dc:creator>Münzel, Thomas</dc:creator>
  <dc:date>2016-07-07</dc:date>
  <dc:description xmlns:ns0="xml" ns0:lang="en">&lt;strong&gt;Background&lt;/strong&gt; Peri-stent coronary evaginations may disturb flow and  have been proposed as possible risk factor for late stent thrombosis. We describe  incidence, predictors, and possible mechanisms of coronary evaginations 12 months  after implantation of bioresorbable vascular scaffolds (BVS).&lt;strong&gt;Methods and  results&lt;/strong&gt; One hundred and two BVS implanted in 90 patients (age 63 ± 13  years, 71 males, 14 diabetics) were analysed with angiography and optical coherence  tomography (OCT) 12 months after implantation. Evaginations were identified as any  hollow in the luminal vessel contour between well-apposed struts and were classified  as major when extending ≥3 mm with a depth ≥10% of the BVS diameter. Fifty-five  (54%) of the BVS (50(56%) of the patients) had at least one evagination (6.1 ± 6.2  evaginations per BVS), with a mean volume of 1.9 ± 1.9 mm³. Major evaginations  were only found in one patient, and in-BVS aneurysms in three patients (4BVS). The  presence of evaginations was strongly associated with that of malapposition  (&lt;em&gt;P&lt;/em&gt; = 0.003) and strut fractures (&lt;em&gt;P&lt;/em&gt; = 0.01). No association  could be shown between the presence and volume of the evaginations and any  clinical variable or the presence of uncovered struts (&lt;em&gt;P&lt;/em&gt; &gt; 0.5). Peri-strut  low- intensity areas (PSLIA) were present in 29 (53%) of the BVS with evaginations  and 12 (26%) of those without (&lt;em&gt;P&lt;/em&gt; = 0.0049); their presence was  independently associated with the presence, the number (&lt;em&gt;P&lt;/em&gt; &lt; 0.003) and  volume of the evaginations (&lt;em&gt;P&lt;/em&gt; = 0.004) and with that of strut fracture.  &lt;strong&gt;Conclusions&lt;/strong&gt; Optical coherence tomography-detected evaginations  are relatively common after BVS implantation, but, as for modern drug-eluting metallic  stents, major evaginations are very rare. Optical coherence tomography evidence of  immature neointima and strut fractures were associated with more severe  development of evaginations.</dc:description>
  <dc:format>application/pdf</dc:format>
  <dc:identifier>https://folia.unifr.ch/global/documents/305047</dc:identifier>
  <dc:identifier>https://folia.unifr.ch/documents/305047/files/coo_cep.pdf</dc:identifier>
  <dc:language>eng</dc:language>
  <dc:relation>info:eu-repo/semantics/altIdentifier/doi/10.1093/eurheartj/ehv581</dc:relation>
  <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
  <dc:rights>License undefined</dc:rights>
  <dc:source>European Heart Journal. - 2016, vol. 37, no. 26, p. 2040–2049</dc:source>
  <dc:subject>info:eu-repo/classification/udc/61</dc:subject>
  <dc:title xmlns:ns1="xml" ns1:lang="en">Coronary evaginations and peri-scaffold aneurysms following implantation of bioresorbable scaffolds: incidence, outcome, and optical coherence tomography analysis of possible mechanisms</dc:title>
  <dc:type>http://purl.org/coar/resource_type/c_6501</dc:type>
</oai_dc:dc>
