<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:creator>Puricel, Serban</dc:creator>
  <dc:creator>Schoepke, Linus</dc:creator>
  <dc:creator>Togni, Mario</dc:creator>
  <dc:creator>Oberhänsli, Markus</dc:creator>
  <dc:creator>Moschovitis, Aris</dc:creator>
  <dc:creator>Meier, Bernhard</dc:creator>
  <dc:creator>Windecker, Stephan</dc:creator>
  <dc:creator>Cook, Stéphane</dc:creator>
  <dc:date>2012</dc:date>
  <dc:description xmlns:ns0="xml" ns0:lang="en">Objectives: We sought to determine the efficacy and safety of a scoring balloon for the  treatment of in-stent restenosis (ISR). Background: The optimal therapy for ISR is not  yet properly established and subject to many discussions. The GRIP™ Balloon  (Acrostak, Switzerland) might be of interest for the treatment of certain types of ISR.  Methods: Between 2003 and 2009, 157 patients who were treated for ISR (182  lesions, 164 interventions) with the GRIP™ balloon were retrieved from our database  and followed clinically. The safety endpoint was the occurrence of immediate coronary  complication (such as perforation or dissection). The efficacy endpoint was freedom  from major adverse cardiac events (MACE: cardiac death, myocardial infarction, and  target lesion revascularisation) at 12-month clinical follow-up. Results: Mean age was  65 ± 11 years and 82% were men. A focal ISR was found in 54% (n = 93) of lesions.  Additional stenting was performed in 22% of lesions after angioplasty with the GRIP™  balloon. There was no perforation as immediate coronary complication whereas  localised dissection was identified in five patients (3%). Survival was 98% at 12  months. MACE occurred in 13% of patients (n = 21). Target lesion revascularisation  (TLR) needed to be performed in 17 (11%). Myocardial infarction occurred in 2 (1%),  and stent thrombosis occurred in 1 (1%) patient. MACE rates were higher in patients  with diffuse ISR (20%) compared with focal ISR (7%) (p = 0.02). Conclusions: Balloon  angioplasty with the GRIP™ balloon for ISR can be safely and successfully  performed, and leads to good clinical outcome in patients presenting with focal ISR.</dc:description>
  <dc:format>application/pdf</dc:format>
  <dc:identifier>https://folia.unifr.ch/unifr/documents/302906</dc:identifier>
  <dc:identifier>https://folia.unifr.ch/documents/302906/files/coo_bau.pdf</dc:identifier>
  <dc:language>eng</dc:language>
  <dc:relation>info:eu-repo/semantics/altIdentifier/doi/10.4414/cvm.2012.00128</dc:relation>
  <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
  <dc:rights>License undefined</dc:rights>
  <dc:source>Cardiovascular Medicine. - 2012, vol. 15, no. 12, p. 354–361</dc:source>
  <dc:subject xmlns:ns1="xml" ns1:lang="en">in-stent restenosis</dc:subject>
  <dc:subject xmlns:ns2="xml" ns2:lang="en">scoring balloon</dc:subject>
  <dc:subject xmlns:ns3="xml" ns3:lang="en">percutaneous coronary intervention</dc:subject>
  <dc:subject>info:eu-repo/classification/udc/61</dc:subject>
  <dc:title xmlns:ns4="xml" ns4:lang="en">Balloon angioplasty using the "grip" scoring balloon for treatment of coronary in-stent restenosis - immediate and 12-month clinical outcomes</dc:title>
  <dc:type>http://purl.org/coar/resource_type/c_6501</dc:type>
</oai_dc:dc>